Setbacks in Haryana

The setback is the open strip that must be left between the building and each boundary. What sets it varies by state — usually the size of the plot, the height of the building, or the width of the road outside.

How far from my boundary must the building sit?

Minimum 0.5 m front and 0.5 m rear.

Code 6.3(2) — and 9 related rules below.

The rules — all 10

Setbacks, core areas — plots up to 60 m²

verbatim

Minimum 0.5 m front and 0.5 m rear.

Code 6.3(2) · Plots up to 60 m²
Plot area up to (m²) 60
Front setback (m) 0.5
Rear setback (m) 0.5

The front setback may be traded, the rear may not

verbatim

Front setbacks can be adjusted to achieve the permissible ground coverage, on the condition that rear setbacks stay fixed. So the rear is the hard boundary and the front is the one with give in it.

Code 6.3(2)(a)

Setbacks, outside core areas — plots up to 75 m²

verbatim

Minimum 1.0 m front and 1.5 m rear. Outside a core area the rear setback is the larger of the two on small plots, which is the reverse of the core-area table.

Code 6.3(3)(i)(a) Note VII · Plots up to 75 m²
Plot area up to (m²) 75
Front setback (m) 1
Rear setback (m) 1.5

Setbacks, core areas — plots above 60 up to 150 m²

verbatim

Minimum 1.5 m front and 1.0 m rear.

Code 6.3(2) · Plots 60–150 m²
Plot area from (m²) 60
Plot area up to (m²) 150
Front setback (m) 1.5
Rear setback (m) 1

Setbacks, outside core areas — plots above 75 up to 150 m²

verbatim

Minimum 1.5 m front and 2.0 m rear.

Code 6.3(3)(i)(a) Note VII · Plots 75–150 m²
Plot area from (m²) 75
Plot area up to (m²) 150
Front setback (m) 1.5
Rear setback (m) 2

Setbacks, core areas — plots above 150 up to 225 m²

verbatim

Minimum 2.5 m front and 2.0 m rear.

Code 6.3(2) · Plots 150–225 m²
Plot area from (m²) 150
Plot area up to (m²) 225
Front setback (m) 2.5
Rear setback (m) 2

Setbacks, outside core areas — plots above 150 up to 250 m²

verbatim

Minimum 2.0 m front and 2.0 m rear.

Code 6.3(3)(i)(a) Note VII · Plots 150–250 m²
Plot area from (m²) 150
Plot area up to (m²) 250
Front setback (m) 2
Rear setback (m) 2

Setbacks, core areas — plots above 225 up to 450 m²

verbatim

Minimum 3.0 m front and 3.0 m rear.

Code 6.3(2) · Plots 225–450 m²
Plot area from (m²) 225
Plot area up to (m²) 450
Front setback (m) 3
Rear setback (m) 3

Setbacks, outside core areas — plots above 250 m²

verbatim

Minimum 3.0 m front and 3.0 m rear. No balcony beyond the rear zoning is permitted.

Code 6.3(3)(i)(a) Note VII · Plots over 250 m²
Plot area from (m²) 250
Front setback (m) 3
Rear setback (m) 3

Setbacks, core areas — plots above 450 m²

verbatim

Minimum 4.5 m front and 4.0 m rear.

Code 6.3(2) · Plots over 450 m²
Plot area from (m²) 450
Front setback (m) 4.5
Rear setback (m) 4
Sources on this page
  • Code 6.3(2)
  • Code 6.3(2)(a)
  • Code 6.3(3)(i)(a) Note VII

Official text: The Haryana Building Code, 2017 ↗

Spotted something wrong?

Rules change and we would rather hear it from you than have somebody build to a stale number. No account needed.

Measure your plot first

Trace your tatima to get the real area, side lengths and a dimensioned plan. Automatic compliance checking runs on Himachal rules today — for Haryana the 45 rules published here are the reference, and the check is yours to make.

Trace your tatima → All Haryana rules →
Ask AI

Nothing matched in the rulebook — try other words (parking, height, fire, setback, water…).

looking it up…

Answers come straight from the building rules for 12 states we cover, plus the glossary and calculators — each with its citation.